4th Hard Drive Carrier May Have Interference Issue in Intel® Server System R1304BTLSHBN

Documentation

Install & Setup

000008404

03/12/2024

Intel has discovered a potential HDD carrier interference issue in the Intel® Server System R1304BTLSHBN when the right rack handle is installed. The issue observed exhibits the following symptom: the fourth HDD carrier can be difficult to install and remove.

The issue has been root-caused to some systems being built with the incorrect rack handle screws. The incorrect rack handle screw length is 6mm, while the correct screw length is 4mm. The incorrect rack handle screw causes a conflict with the fourth HDD carrier.

There was a manufacturing excursion at the Intel chassis factory, and some Intel Server Systems R1304BTLSHBN were built with the incorrect rack handle screws.

Please refer to the below PDF file for the serial numbers of Intel Server SystemsR1304BTLSHBN which are affected by this technical advisory.

Technical Advisory 979 (PDF) icon
File name: TA_0979-01.pdf
Size: 55 KB
Date: June 2011