Article ID: 000074393 Content Type: Troubleshooting Last Reviewed: 12/11/2015

Gen3 x2 Example Design Simulation Issue

Environment

  • Quartus® II Subscription Edition
  • PCI Express
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    The Arria 10 Gen3 x2 example design might timeout when performing an MSI DMA Read and issue the following error message:

    INFO: 109129 ns TASK:chained_dma_test

    INFO: 109129 ns DMA: Read

    INFO: 109129 ns msi_address (RC memory)= 0x0FF0

    INFO: 114477 ns Polling MSI Address:0FF0---> Data:FADE......

    FATAL: 514277 ns MSI timeout occurred, MSI never received, Test Fails

    FAILURE: Simulation stopped due to Fatal error!

    Resolution

    This issue is fixed in version 14.0 of the Quartus II software.

    Related Products

    This article applies to 1 products

    Intel® Arria® 10 FPGAs and SoC FPGAs