Article ID: 000074474 Content Type: Troubleshooting Last Reviewed: 08/13/2012

Why am I unable to sample pins that are configured as outputs when performing Boundary Scan testing on my programmed MAX II device?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

By default, the input buffers are turned off for I/O pins that are configured as outputs in your MAX® II device.

To regenerate your programming file to enable the input buffers, you need to set the 'Always Enable Input Buffers' option in the Quartus® II software and re-run the Assembler.

 

This option is in the Assembler section under the Assignments/Settings menu in the Quartus II software.

 

For more information, refer to the BST for Programmed Devices section in IEEE 1149.1 (JTAG) Boundary-Scan Testing for MAX II Devices (PDF).