Critical Issue
Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 20.2, you may see a similar error to the one shown below when a calibration failure occurs in the Intel Stratix® 10 EMIF Unified Calibration Debug Toolkit or the Intel Agilex® 3 FPGA EMIF Debug Toolkit.
SEVERE: An error occurred while running script"::emif_cal_dbg::odt_cal::run_odt_cal_callback
": ed_synth_inst: key "65542" not known in dictionary
while executing
"dict get $dictionary $key"
(procedure "::emif_cal_dbg::util::family_expert::get_dict_elem" line 3)
invoked from within
"::emif_cal_dbg::util::family_expert::get_dict_elem cal_stage [expr $val]"
This example error message displays an error code “65542” when a calibration failure occurs and is not reported by the EMIF Toolkit.
For the Intel® Stratix® 10 EMIF Unified Calibration Debug Toolkit, below is a list of the calibration stages and associated error codes that are not reported.
Calibration Stage Error Code
WRITE_LEVEL_EDGE 65541
WRITE_LEVEL_CLOCK 131077
WRITE_DESKEW_DM_CENTER 65542
MARGINING_DQ 65547
MARGINING_DM 131083
For the Intel Agilex® 3 FPGA EMIF Debug Toolkit, below is a list of the calibration stages and associated error codes that are not reported.
Calibration Stage Error Code
WRITE_LEVEL_EDGE: 65541
WRITE_LEVEL_CLOCK: 131077
WRITE_DESKEW_DM_CENTER: 65542
READ_DESKEW_DBI_CENTER: 65540