Article ID: 000081589 Content Type: Install & Setup Last Reviewed: 04/22/2015

Are there any problems when performing dynamic reconfiguration of Arria V GZ and Stratix V device non-PCI Express channels when PCI Express CvP is enabled in Quartus II software version 13.1?

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Yes, due to a bug in Quartus® II software version 13.1, you may see problems performing dynamic reconfiguration of Stratix® V and Arria® V GZ device non-PCI Express channels when PCI Express CvP is enabled in the PCIe Hard IP and the Device and Pin Settings (CvP Options) dialog box.

    The following devices are affected.

    5SGXB5, 5SGXB6

    5SGXA9, 5SGXAB, 5SGXB9, 5SGXBB

    5SGXA3, 5SGXA4, 5SGSD4, 5SGSD5, 5AGZE5, 5AGZE7

    Resolution

    To work around this problem, you can install Quartus II software version 13.1 Update 3 and then download and install patch 3.10 from the links below.

    This problem is scheduled to be fixed in a future version of the Quartus II software.

    Related Products

    This article applies to 1 products

    Stratix® V GX FPGA