Article ID: 000091152 Content Type: Troubleshooting Last Reviewed: 01/06/2023

Why does the F-Tile FHT Transceiver Toolkit RX PRBS checker immediately display a large number of error bits upon starting it and doesn’t change anymore in the Intel® Quartus® Prime Pro Edition Software v22.1?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem with the Programmer in the Intel® Quartus® Prime Pro Edition Software version 22.1, the F-Tile FHT Transceiver Toolkit RX PRBS checker immediately displays a large number of error bits as the start button is pressed.

    Resolution

    This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition Software version 22.3.
    To work around this problem in the Intel® Quartus® Prime Pro Edition Software v22.2 or earlier, follow these steps:

    1. Program the device with the Programmer in the Intel® Quartus® Prime Pro Edition Software v21.4 and earlier.
    2. Run the F-Tile FHT Transceiver Toolkit in the Intel Quartus Prime Pro Edition Software v22.1.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs I-Series