Article ID: 000092265 Content Type: Connectivity Last Reviewed: 08/25/2023

How to add an assignment for F-Tile of Intel Agilex® 7 FPGA DC coupling in the Intel® Quartus® Prime Pro Edition Software version 22.4 and earlier?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.4 and earlier, there is no valid assignment value for the F-Tile of the Intel Agilex® 7 FPGA DC coupling connection.

     

     

     

    Resolution

    This problem has been resolved in the Intel® Quartus® Prime Pro Edition Software version 23.1. 

    Assignment example as below:

    set_instance_assignment -name HSSI_PARAMETER "flux_mode = FLUX_MODE_BYPASS" -to <ip_instance_hpath> <tileid>

    set_instance_assignment -name HSSI_PARAMETER "rx_ac_couple_enable = DISABLE" -to <ip_instance_hpath> <tileid>

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs I-Series