4.2.4. 1000BASE-X and 1000BASE-KX Supported Features

The following features are supported by the transceivers in 1000BASE-X and 1000BASE-KX configurations.

8B/10B Encoder in 1000BASE-X and 1000BASE-KX Configurations

In 1000BASE-X and 1000BASE-KX modes, the 8B/10B encoder clocks in 8-bit data and 1-bit control identifiers from the transmitter phase compensation FIFO and generates 10-bit encoded data. The 10-bit encoded data is fed to the serializer.

Idle Ordered-Set Generation in 1000BASE-X and 1000BASE-KX Configurations

The IEEE 802.3 specification requires the 1000BASE-X and 1000BASE-KX PHY to transmit idle ordered sets (/I/) continuously and repetitively whenever the GMII is idle. This ensures that the receiver maintains bit and word synchronization whenever there is no active data to be transmitted.

In 1000BASE-X and 1000BASE-KX functional modes, any /Dx.y/ following a /K28.5/ comma is replaced by the transmitter with either a /D5.6/ (/I1/ ordered set) or a /D16.2/ (/I2/ ordered set), depending on the current running disparity. The exception is when the data following the /K28.5/ is /D21.5/ (/C1/ ordered set) or /D2.2/ (/C2/) ordered set. If the running disparity before the /K28.5/ is positive, an /I1/ ordered set is generated. If the running disparity is negative, a /I2/ ordered set is generated. The disparity at the end of a /I1/ is the opposite of that at the beginning of the /I1/. The disparity at the end of a /I2/ is the same as the beginning running disparity (right before the idle code). This ensures a negative running disparity at the end of an idle ordered set. A /Kx.y/ following a /K28.5/ is not replaced.

Note: /D14.3/, /D24.0/, and /D15.8/ are replaced by /D5.6/ or /D16.2/ (for /I1/, /I2/ ordered sets). /D21.5/ (part of the /C1/ order set) is not replaced.
Figure 94. Example of Automatic Ordered Set Generation


Reset Condition in 1000BASE-X and 1000BASE-KX Configurations

After deassertion of tx_digitalreset, the 1000BASE-X and 1000BASE-KX transmitters automatically transmit three /K28.5/ comma code groups before transmitting user data on the tx_datain port. This could affect the synchronization state machine behavior at the receiver.

Depending on when you start transmitting the synchronization sequence, there could be an even or odd number of /Dx.y/ code groups transmitted between the last of the three automatically sent /K28.5/ code groups and the first /K28.5/ code group of the synchronization sequence. If there is an even number of /Dx.y/ code groups received between these two /K28.5/ code groups, the first /K28.5/ code group of the synchronization sequence begins at an odd code group boundary (rx_even = FALSE). An IEEE802.3-compliant 1000BASE-X or 1000BASE-KX synchronization state machine treats this as an error condition and goes into the loss of sync state.

The following figure shows an example of even numbers of /Dx.y/ between the last automatically sent /K28.5/ and the first user-sent /K28.5/. The first user-sent /K28.5/ code group received at an odd code group boundary in cycle n + 3 takes the receiver synchronization state machine in the loss of sync state. The first synchronization ordered set /K28.5/Dx.y/ in cycles n + 3 and n + 4 is discounted and three additional ordered sets are required for successful synchronization.

Figure 95. Example of Reset Condition in 1000BASE-X and 1000BASE-KX Configurations


Rate Match FIFO in 1000BASE-X and 1000BASE-KX Configurations

In 1000BASE-X and 1000BASE-KX modes, the rate match FIFO is capable of compensating for up to ±100 ppm (200 ppm total) difference between the upstream transmitter and the local receiver reference clock. The 1000BASE-X and 1000BASE-KX protocols require the transmitter to send idle ordered sets /I1/ (/K28.5/D5.6/) and /I2/ (/K28.5/D16.2/) during inter-packet gaps adhering to the rules listed in the IEEE 802.3 specification.

The rate match operation begins after the synchronization state machine in the word aligner indicates synchronization is acquired by driving the rx_syncstatus signal high. The rate matcher deletes or inserts both symbols (/K28.5/ and /D16.2/) of the /I2/ ordered sets even if it requires deleting only one symbol to prevent the rate match FIFO from overflowing or under-running. It can insert or delete as many /I2/ ordered sets as necessary to perform the rate match operation.

The following figure shows an example of rate match FIFO deletion where three symbols are required to be deleted. Because the rate match FIFO can only delete /I2/ ordered set, it deletes two /I2/ ordered sets (four symbols deleted).

Figure 96. Example of Rate Match Deletion in 1000BASE-X and 1000BASE-KX Configurations


The following figure shows an example of rate match FIFO insertion in the case where one symbol is required to be inserted. Because the rate match FIFO can only delete /I2/ ordered set, it inserts one /I2/ ordered set (two symbols inserted).

Figure 97. Example Rate Match Insertion in 1000BASE-X and 1000BASE-KX Configurations


Two register bits, rx_rmfifodatadeleted and rx_rmfifodatainserted, indicate rate match FIFO deletion and insertion events. Both the rx_rmfifodatadeleted and rx_rmfifodatainserted status flags are latched High during deleted and inserted /I2/ ordered sets.

Note: If you have the autonegotiation state machine in the FPGA, note that the rate match FIFO is capable of inserting or deleting the first two bytes (/K28.5//D2.2/) of /C2/ ordered sets during autonegotiation. However, the insertion or deletion of the first two bytes of /C2/ ordered sets can cause the autonegotiation link to fail. For more information, refer to the Altera Knowledge Base Support Solution.

Word Aligner in 1000BASE-X and 1000BASE-KX Configurations

The word aligner in 1000BASE-X and 1000BASE-KX functional modes is configured in automatic synchronization state machine mode. The Quartus II software automatically configures the synchronization state machine to indicate synchronization when the receiver receives three consecutive synchronization ordered sets. A synchronization ordered set is a /K28.5/ code group followed by an odd number of valid /Dx.y/ code groups. The fastest way for the receiver to achieve synchronization is to receive three continuous {/K28.5/, /Dx.y/} ordered sets.

Receiver synchronization is indicated on the rx_syncstatus port of each channel. A high on the rx_syncstatus port indicates that the lane is synchronized; a low on the rx_syncstatus port indicates that the lane has fallen out of synchronization. The receiver loses synchronization when it detects four invalid code groups separated by less than three valid code groups or when it is reset.